<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-11 03-31-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.10 MHz 5/5, 61 dBuV CLASSIQ
Pilot RDS Phase Difference
7.1 kHz 3.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 70 kHz 10120 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
1,5 dBr 2,71 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CLASSIQ " F221 0 (No PTY) 1 0 1 2 3:31, 11.01.2025
RT
"Schumann : Concerto pour piano et orchestre "
AF EON
87.6, 87.8, 88.2, 88.3, 88.5, 88.6, 90.8, 92.9, 94.5, 94.9, 96.5, 98.7, 99.0, 99.9, 100.9, 101.1, 101.4, 103.0, 106.1, 106.4, 107.3 MHz -
FM Scope Station: 101.10 MHz, signal: 5/5 (61 dBuV) Max at: 70 kHz MIN: 11 kHz % above 75 kHz: 0,0000 Acquired: 2025/01/11 3:30:43 Total samples: 10120 Equivalent time: 0:08:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 3,6 dBr MIN: 1,5 dBr AVE: 2,71 dBr % above 10,0 dBr: 0,0 Last value: 2,4 dBr (2025/01/11 3:30:42) Station: 101.10 MHz, signal: 5/5 (61 dBuV) 03:24 03:25 03:26 03:27 03:28 03:29 03:30 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality